中華黃頁網路電話簿
PCM

PCM ( E1 ) Swith board Cable (each pair Individually shielded)

介紹

This cable is used for interconnecting between frames of PCM equipments with 120W characteristic impedance.
1.Application:This cable is used for interconnecting between frames of PCM equipments with 120W characteristic impedance.2. Conductor:Annealed bare copper or tinned copper3. Insulation:Foamed PE / HDPE4.Shielded:Two wires are twisted to form a pair then shielded with a layer of Al-Mylar foil. A piece of tinned copper wire is added along with the pair as drain wire.5.Assembly:Suitable number of pairs are assembled to form a cable core.6. Overall shield:a. Layer of Al-Mylar foil with a drain wire.7.Sheath:PVC (polyvinyl Chloride)or LSNHFRPE.( ow-moke Non-Halogen Flame Retardant Polyethylene).
8. Structure:




Conducyor

Pair

Insulation

Cable core

Sheath

Overall

Standard


Diameter(mm)

(P)

Diameter(mm)

Diameter(mm)

Thickness(mm)

Diameter(mm)

Length(M)


0.5

1

1.3

3.5

0.6

5.0

200


2

6.0

0.6

7.5

200


4

7.0

0.6

8.5

500


8

10.0

0.6

11.5

500


10

10.0

0.6

11.5

500


16

13.5

0.8

16.0

500


22

16.0

1.0

18.3

500


25

16.0

1.0

18.5

500


32

19.0

1.0

21.5

500


40

21.0

1.5

24.5

500
9. Characteristics:




Items

Specification


Conductor Resistance ( 20℃ )

Max.100.2W / Km


Conductor Resistance unbalance( 20℃ )

Max.5 ﹪


Insulation Resistance ( 20℃,DC 500V / 1min.)

Min .5000M - Km


Dielectric strength

DC 1000V / 1min. Between Conductors


DC 1500V / 1min. Between Conductors and shield


Static Capacitance (1KHz)

Max.50 nf / Km


Attenuation. (1024 KHz)

Max.34 dB / Km


Characteristic Impedance (1024 KHz)

120 ± 10W


Near-end cross talk (1024 KHz)

Min.70 dB / 500M

10. Marking:TATUNG CO. PCM – E1 0.5 ´ð P yearðM