中華黃頁網路電話簿
PE-PVC

PE-PVC

介紹

This cable is a polyethylene insulated, PVC sheathed, unit type cable for indoor installation.
1. Scope
This cable is a polyethylene insulated, PVC sheathed, unit type cable for indoor installation.

2. Wire Construction:





Wire Quad NO.

A-wire

B-wire

C-wire

D-wire


1

Blue

White

Brown

Black


2

Yellow

White

Brown

Black


3

Green

White

Brown

Black


4

Red

White

Brown

Black


5

Violet

White

Brown

Black

3.Core Forming:
6P~200P





Pair

PE tape

Pair

PE tape

pair

PE tape


1-10P

Blue-Blue

71-80P

Green-White

141-150P

Violet-Brown


11-20P

Yellow-Yellow

81-90P

Red-White

151-160P

Blue-Black


21-30P

Green-Green

91-100P

Violet-White

161-170P

Yellow-Black


31-40P

Red-Red

101-110P

Blue-Brown

171-180P

Green-Black


41-50P

Violet-Violet

111-120P

Yellow-Brown

181-190P

Red-Black


51-60P

Blue-White

121-130P

Green-Brown

191-200P

Violet-Black


61-70P

Yellow-White

131-140P

Red-Brown





300P~600P




Pair

PE tape

Pair

PE tape

pair

PE tape


1-50P

Blue-Blue

201-250P

Violet-Violet

401-450P

Red-White


51-100P

Yellow-Yellow

251-300P

Blue-White

451-500P

Violet-White


1011-150P

Green-Green

301-350P

Yellow-White

501-550P

Blue-Brown


151-200P

Red-Red

351-400P

Green-White

551-600P

Yellow-Brown

4.Structure:
4.1. Conductor:0.4±0.01mm、0.5±0.01mm
4.2. Number of pair:6、10、20、30、50、100、200、300、400、600
4.3. Insulation:PE
4.4. Twisted:Four insulated conductor shall be twisted together
4.5. Assembly:Arranged in accordance with the structure figure
4.6. Core Wrap:0.025mm Thickness , mylar tape Min(overlap ratio 33%)
4.7. Drain wire:7/0.16 Tinned Copper Wire
4.8. Shield:0.05mm Thickness , Al-mylar tape Min(overlap ratio 33%) ,with Al side in
4.9. Sheath:PE

5. Standards:




Dia. of conductor
(mm)

No. of pair
(P)

Insulation thickness
(mm)

cable core diameter (mm) approx.

Sheath thickness
(mm)

overall diameter (mm) approx.

estimated weight (Kg/m)

Standard length
(M)




6

0.13

4

1.3

7

52

500




10

0.13

5

1.3

8

69

500




20

0.13

6

1.3

9

109

500




30

0.13

7

1.3

10

143

500


0.4

50

0.13

10

1.4

13

218

500




100

0.13

14

1.6

17

397

500




200

0.13

18

1.9

22

746

500




300

0.13

23

2.0

27

1076

500




400

0.13

26

2.3

31

1427

500




600

0.13

31

2.4

36

2061

500




6

0.15

5

1.3

8

67

500




10

0.15

6

1.3

9

90

500




20

0.15

7

1.3

10

146

500




30

0.15

9

1.3

12

198

500


0.5

50

0.15

12

1.4

15

309

500




100

0.15

16

1.6

20

565

500




200

0.15

22

2.0

26

1087

500




300

0.15

27

2.1

31

1577

500




400

0.15

31

2.4

36

2092

500




600

0.15

38

2.5

43

3044

500

6. Electric Properties:




Item

0.4

0.5


Conductor resistance

Standard value:139Ω/KMMax. value:147.5Ω/KM

Standard value:88.7Ω/KMMax. value:93.5Ω/KM


Mutual capacitance

50P↑→ 55 nf/km ↓,30P ↓→ 60 nf/km ↓


Dielectric strength

DC 500V / 1min. or AC 350 V / 1min.


Insulation resistance

5000MW- Km DC 250~500V


Near-End Cross-talk

40KHz,AC
Min value:58.5dB↑Average value:66dB↑


Far-End Cross-talk

160KHz,AC
m-1.28×S≧55dB/㎞以上 m:Average value S:Standard value
Min value:38dB/km↑