600V Second Type EPR (Ethylene Propylene Rubber) Insulated Neoprene Sheathed Flexible Cables (2PNCT). It shall comply with the standard of CNS 10741.
Features
Construction:(1) Conductor: tinned soft annealed stranded flexible copper wires (2) Insulation: EPR (3) Two or more cores are twisted together,cable core covered with proper separator (4) Sheath: Neoprene Introduction: The 2PNCT portable Cable with flexible conductor is used for Electric Machinery and Apparatus. The EPR insulated Neoprene (Polyvinyl Chloride) sheathed portable cable has excellent flexibility. It can withstand impact, bending, abrasion, elongation etc.. It has excellent oil-resistant and chemical-resistant properties. It has excellent heat-resistant, weatherproof properties.
Specifications
600V 2PNCT SINGLE CORE CABLE Refer to CNS 10741
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
StandardLength
M
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
0.75
30/0.18
1.1
0.8
5.8
48
200
1.25
50/0.18
1.5
0.8
6.2
60
200
2.0
37/0.26
1.8
0.8
6.5
70
200
3.5
45/0.32
2.5
0.8
7.4
95
200
5.5
70/0.32
3.1
1.0
8.4
130
200
8
50/0.45
3.7
1.0
9.2
165
200
14
88/0.45
4.9
1.0
11.0
240
200
22
7/20/0.45
7.0
1.2
13.5
375
200
30
7/27/0.45
8.1
1.2
15.0
470
200
38
7/34/0.45
9.1
1.2
16.0
570
200
50
19/16/0.45
10.4
1.5
18.0
720
200
60
19/20/0.45
11.6
1.5
19.5
870
200
80
19/27/0.45
13.5
2.0
23
1180
200
100
19/34/0.45
15.2
2.0
25
1430
200
600V 2PNCT TWO CORE CABLE Refer to CNS 10741
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
StandardLength
M
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
0.75
30/0.18
1.1
0.8
9.0
115
200
1.25
50/0.18
1.5
0.8
9.8
140
200
2.0
37/0.26
1.8
0.8
11.0
175
200
3.5
45/0.32
2.5
0.8
12.5
245
200
5.5
70/0.32
3.1
1.0
14.5
350
200
8
50/0.45
3.7
1.0
16.0
435
200
14
88/0.45
4.9
1.0
18.5
640
200
22
7/20/0.45
7.0
1.2
25
1070
200
30
7/27/0.45
8.1
1.2
27
1340
200
38
7/34/0.45
9.1
1.2
30
1630
200
50
19/16/0.45
10.4
1.5
34
2100
200
60
19/20/0.45
11.6
1.5
37
2520
200
80
19/27/0.45
13.5
2.0
43
3470
200
100
19/34/0.45
15.2
2.0
47
4200
200
600V 2PNCT THREE CORE CABLE Refer to CNS 10741
Conductor
Thickness of insulation
mm
Approx.
Overall Diameter
mm
Approx.
Weight
Kg/km
Standard
Length
M
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer Diameter
Approx.
mm
0.75
30/0.18
1.1
0.8
10.5
160
200
1.25
50/0.18
1.5
0.8
11.5
195
200
2.0
37/0.26
1.8
0.8
12.5
245
200
3.5
45/0.32
2.5
0.8
14.5
355
200
5.5
70/0.32
3.1
1.0
17.0
515
200
8
50/0.45
3.7
1.0
18.5
655
200
14
88/0.45
4.9
1.0
22
1000
200
22
7/20/0.45
7.0
1.2
29
1670
200
30
7/27/0.45
8.1
1.2
32
2100
200
38
7/34/0.45
9.1
1.2
35
2550
200
50
19/16/0.45
10.4
1.5
40
3320
200
60
19/20/0.45
11.6
1.5
44
4020
200
80
19/27/0.45
13.5
2.0
51
5500
200
100
19/34/0.45
15.2
2.0
56
6720
200
600V 2PNCT FOUR CORE CABLE Refer to CNS 10741
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
StandardLength
M
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
0.75
30/0.18
1.1
0.8
9.4
130
200
1.25
50/0.18
1.5
0.8
10.5
175
200
2.0
37/0.26
1.8
0.8
11.5
200
200
3.5
45/0.32
2.5
0.8
13.0
290
200
5.5
70/0.32
3.1
1.0
15.5
415
200
8
50/0.45
3.7
1.0
17.0
525
200
14
88/0.45
4.9
1.0
20
795
200
22
7/20/0.45
7.0
1.2
27
1330
200
30
7/27/0.45
8.1
1.2
29
1670
200
38
7/34/0.45
9.1
1.2
32
2020
200
50
19/16/0.45
10.4
1.5
36
2620
200
60
19/20/0.45
11.6
1.5
39
3150
200
80
19/27/0.45
13.5
2.0
46
4320
200
100
19/34/0.45
15.2
2.0
50
5270
200