600V Grade Polyvinyl Chloride Insulated and Sheathed Control Cables (Code designation: CVV). It is used at wiring for control circuit. The cables shall comply with the standard of CNS 4898.
Features
Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2)Insulation: PVC. (3) Two or more cores are twisted together,cable core covered with proper separator (4) Sheath: PVC Introduction:Polyvinyl chloride (PVC) is a chemical compound of high degree of polymerization with characteristics of high insulation and abrasion-resistant, weatherproof. The PVC control cable has labeled our National Quality Standard.
Specifications
600V PVC Insulated and PVC Sheathed Control Cable (CVV)
Number Of cores
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
StandardLength
M
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
2
1.25
7/0.45
1.35
0.8
9.4
100
300
2.0
7/0.6
1.8
0.8
10.5
130
300
3.5
7/0.8
2.4
0.8
11.5
180
300
5.5
7/1.0
3.0
1.0
13.5
250
300
8
7/1.2
3.6
1.2
15.5
340
300
8
*
3.4
1.2
15.0
330
300
14
7/1.6
4.8
1.4
19.0
530
300
14
*
4.4
1.4
18.0
505
300
22
7/2.0
6.0
1.6
23.
770
300
22
*
5.5
1.6
21
730
300
3
1.25
7/0.45
1.35
0.8
9.9
120
300
2.0
7/0.6
1.8
0.8
11.0
160
300
3.5
7/0.8
2.4
0.8
12.5
225
300
5.5
7/1.0
3.0
1.0
14.5
320
300
8
7/1.2
3.6
1.2
16.5
440
300
8
*
3.4
1.2
16.0
430
300
14
7/1.6
4.8
1.4
20
690
300
14
*
4.4
1.4
19
660
300
22
7/2.0
6.0
1.6
24
1040
300
22
*
5.5
1.6
23
980
300
4
1.25
7/0.45
1.35
0.8
11.0
150
300
2.0
7/0.6
1.8
0.8
12.0
200
300
3.5
7/0.8
2.4
0.8
13.5
280
300
5.5
7/1.0
3.0
1.0
16.0
405
300
8
7/1.2
3.6
1.2
18.0
560
300
8
*
3.4
1.2
17.5
540
300
14
7/1.6
4.8
1.4
23
900
300
14
*
4.4
1.4
21
845
300
22
7/2.0
6.0
1.6
27
1340
300
22
*
5.5
1.6
25
1270
300
* Compacted stranded conductor
600V PVC Insulated and PVC Sheathed Control Cable (CVV)
Number Of cores
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
StandardLength
M
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
5
1.25
7/0.45
1.35
0.8
11.5
175
300
2.0
7/0.6
1.8
0.8
13.0
240
300
3.5
7/0.8
2.4
0.8
14.5
340
300
5.5
7/1.0
3.0
1.0
17.0
490
300
8
7/1.2
3.6
1.2
20
685
300
8
*
3.4
1.2
18.5
660
300
14
7/1.6
4.8
1.4
25
1110
300
14
*
4.4
1.4
24
1050
300
6
1.25
7/0.45
1.35
0.8
12.5
200
300
2.0
7/0.6
1.8
0.8
14.3
280
300
3.5
7/0.8
2.4
0.8
15.5
400
300
5.5
7/1.0
3.0
1.0
18.5
580
300
8
7/1.2
3.6
1.2
22
810
300
8
*
3.4
1.2
21
780
300
14
7/1.6
4.8
1.4
27
1330
300
14
*
4.4
1.4
26
1250
300
7
1.25
7/0.45
1.35
0.8
12.5
220
300
2.0
7/0.6
1.8
0.8
14.0
300
300
3.5
7/0.8
2.4
0.8
15.5
430
300
5.5
7/1.0
3.0
1.0
18.5
640
300
8
7/1.2
3.6
1.2
22
900
300
8
*
3.4
1.2
21
865
300
8
1.25
7/0.45
1.35
0.8
13.5
250
300
2.0
7/0.6
1.8
0.8
15.0
340
300
3.5
7/0.8
2.4
0.8
17.0
500
300
5.5
7/1.0
3.0
1.0
21
730
300
8
7/1.2
3.6
1.2
24
1040
300
8
*
3.4
1.2
23
975
300
* Compacted stranded conductor
600V PVC Insulated and PVC Sheathed Control Cable (CVV)
Number Of cores
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
StandardLength
M
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
10
1.25
7/0.45
1.35
0.8
15.5
310
300
2.0
7/0.6
1.8
0.8
17.5
430
300
3.5
7/0.8
2.4
0.8
19.5
630
300
5.5
7/1.0
3.0
1.0
24
940
300
8
7/1.2
3.6
1.2
29
1360
300
8
*
3.4
1.2
28
1290
300
12
1.25
7/0.45
1.35
0.8
16.0
350
300
2.0
7/0.6
1.8
0.8
18.0
490
300
3.5
7/0.8
2.4
0.8
21
720
300
5.5
7/1.0
3.0
1.0
25
1100
300
8
7/1.2
3.6
1.2
30
1560
300
8
*
3.4
1.2
29
1500
300
15
1.25
7/0.45
1.35
0.8
17.0
405
300
2.0
7/0.6
1.8
0.8
19.0
575
300
3.5
7/0.8
2.4
0.8
22
855
300
5.5
7/1.0
3.0
1.0
27
1310
300
20
1.25
7/0.45
1.35
0.8
19.0
515
300
2.0
7/0.6
1.8
0.8
22
735
300
3.5
7/0.8
2.4
0.8
25
1130
300
5.5
7/1.0
3.0
1.0
31
1730
300
30
1.25
7/0.45
1.35
0.8
23
735
300
2.0
7/0.6
1.8
0.8
26
1100
300
3.5
7/0.8
2.4
0.8
30
1670
300
* Compacted stranded conductor