600V Mica layer, Cross-Linked Polyethylene Insulated, Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power Cables. It is used at wiring for emergency power and fire-fighting equipment. The cables shall comply with the standard of CNS 11359 .
Features
Construction:(1) Conductor: untinned soft annealed stranded or solid copper wires (2) Mica tape (3) Insulation: XLPE. (4) Two or more cores are twisted together,cable core covered with proper separator (5) Sheath: LSHF Introduction: 600V Mica layer, Cross-Linked Polyethylene Insulated, Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power Cables (FR-CL). It has following characteristics: (1) Low toxicity index; per NES 713; toxicity index <=5 (2) Don’t produce halogen gas; per IEC 60754-1; Amount of HCL gas <=0.5% (3) Low smoke; LSHF compound per ASTM E662 smoke density test; Ds<=250,VOF4<=100 (4) Excellent flame resistance; per ASTM D2863 oxygen index; OI >=30; per IEEE 383 vertical open tray flame test; passed. The Low-Smoke and Halogen-Free (LSHF) wire and cable could minimize the lowest damage in case of fire. Therefore, the public areas, such as subway, tunnel, railway, public building, substreet, ships, power stations, school, hospital, and rapid transit system in more suitable to install the LSHF cable to secure the human lives and properties.
Specifications
600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL)
Number Of cores
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
1
-
1/1.0
1.0
0.8
6.4
55
-
1/1.2
1.2
0.8
6.6
60
-
1/1.6
1.6
0.8
7.0
70
-
1/2.0
2.0
0.8
7.4
85
-
1/2.6
2.6
1.0
8.4
120
0.9
7/0.4
1.2
0.8
6.7
55
1.25
7/0.45
1.35
0.8
6.8
60
2.0
7/0.6
1.8
0.8
7.2
75
3.5
7/0.8
2.4
0.8
7.8
93
5.5
7/1.0
3.0
1.0
8.8
125
8
*
3.4
1.0
9.2
146
14
*
4.4
1.0
10.5
211
22
*
5.5
1.2
12.0
313
30
*
6.5
1.2
13.0
406
38
*
7.3
1.2
14.0
479
50
*
8.5
1.5
16.0
609
60
*
9.3
1.5
16.5
703
80
*
10.8
1.5
18.0
897
100
*
12.0
2.0
20
1120
125
*
13.5
2.0
22
1430
150
*
14.7
2.0
23
1580
200
*
17.0
2.5
27
2190
250
*
19.0
2.5
29
2670
325
*
21.7
2.5
32
3390
400
*
24.1
2.5
34.5
4100
500
*
26.9
3.0
38.5
5180
* Compacted stranded conductor
600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL)
Number Of cores
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
2
8
*
3.4
1.0
16.0
305
14
*
4.4
1.0
18.5
468
22
*
5.5
1.2
21.5
668
30
*
6.5
1.2
23.5
867
38
*
7.3
1.2
25.5
1080
50
*
8.5
1.5
29
1380
60
*
9.3
1.5
31
1610
80
*
10.8
1.5
34
2050
100
*
12.0
2.0
39
2610
125
*
13.5
2.0
43
3190
150
*
14.7
2.0
45
3700
200
*
17.0
2.5
53
4920
250
*
19.0
2.5
57
6000
325
*
21.7
2.5
63
7580
400
*
24.1
2.5
68
9170
500
*
26.9
3.0
76
11600
3
8
*
3.4
1.0
17.0
401
14
*
4.4
1.0
19.5
627
22
*
5.5
1.2
23
920
30
*
6.5
1.2
25.5
1220
38
*
7.3
1.2
27.5
1490
50
*
8.5
1.5
31.5
1910
60
*
9.3
1.5
33.5
2230
80
*
10.8
1.5
37
2860
100
*
12.0
2.0
42
3620
125
*
13.5
2.0
46
4480
150
*
14.7
2.0
49
5200
200
*
17.0
2.5
57
6800
250
*
19.0
2.5
60.5
8420
325
*
21.7
2.5
67
10700
400
*
24.1
2.5
74
12900
500
*
26.9
3.0
83
16400
* Compacted conductor
600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL)
Number Of cores
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
4
-
1/1.0
1.0
0.8
12
150
-
1/1.2
1.2
0.8
12.5
170
-
1/1.6
1.6
0.8
13.5
218
-
1/2.0
2.0
0.8
14.5
274
-
1/2.6
2.6
1.0
16.5
396
0.9
7/0.4
1.2
0.8
12.2
156
1.25
7/0.45
1.35
0.8
13.0
176
2.0
7/0.6
1.8
0.8
14.0
222
3.5
7/0.8
2.4
0.8
15.5
301
5.5
7/1.0
3.0
1.0
17.5
421
8
*
3.4
1.0
18.5
505
14
*
4.4
1.0
22
800
22
*
5.5
1.2
25.5
1190
30
*
6.5
1.2
28
1640
38
*
7.3
1.2
30.5
1930
50
*
8.5
1.5
35
2480
60
*
9.3
1.5
37
2900
80
*
10.8
1.5
41
3740
100
*
12.0
2.0
47
4820
125
*
13.5
2.0
51
5820
150
*
14.7
2.0
54
6800
200
*
17.0
2.5
63
8990
250
*
19.0
2.5
68
11000
325
*
21.7
2.5
75
14000
400
*
24.1
2.5
82
17000
500
*
26.9
3.0
92
21600
* Compacted conductor
600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL)
Number Of cores
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
5
-
1/1.0
1.0
0.8
13
175
-
1/1.2
1.2
0.8
13.5
200
-
1/1.6
1.6
0.8
14.5
250
-
1/2.0
2.0
0.8
15.5
330
-
1/2.6
2.6
1.0
18.5
430
0.9
7/0.4
1.2
0.8
13
160
1.25
7/0.45
1.35
0.8
14
207
2.0
7/0.6
1.8
0.8
15
260
3.5
7/0.8
2.4
0.8
17
360
5.5
7/1.0
3.0
1.0
20
510
8
*
3.4
1.0
21
613
14
*
4.4
1.0
24
955
22
*
5.5
1.2
28
1480
30
*
6.5
1.2
31
1960
6
-
1/1.0
1.0
0.8
14
200
-
1/1.2
1.2
0.8
15
230
-
1/1.6
1.6
0.8
16
300
-
1/2.0
2.0
0.8
17
380
-
1/2.6
2.6
1.0
20.5
480
0.9
7/0.4
1.2
0.8
14.5
170
1.25
7/0.45
1.35
0.8
15.5
240
2.0
7/0.6
1.8
0.8
16.5
310
3.5
7/0.8
2.4
0.8
18.5
420
5.5
7/1.0
3.0
1.0
21.5
600
8
*
3.4
1.0
22
724
14
*
4.4
1.0
26
1190
22
*
5.5
1.2
31
1770
30
*
6.5
1.2
34
2320
* Compacted conductor
600V Mica tape, XLPE insulated and LSHF sheathed fire-resistant cables (FR-CL)
Number Of cores
Conductor
Thickness of insulation
mm
Approx.Overall Diameter
mm
Approx.Weight
Kg/km
Normative Cross Area
mm2
Number/ Diameter of Wires
No./mm
Outer DiameterApprox.
mm
7
-
1/1.0
1.0
0.8
14
210
-
1/1.2
1.2
0.8
15
240
-
1/1.6
1.6
0.8
16
320
-
1/2.0
2.0
0.8
17
410
-
1/2.6
2.6
1.0
20.5
570
0.9
7/0.4
1.2
0.8
14.5
190
1.25
7/0.45
1.35
0.8
15.5
250
2.0
7/0.6
1.8
0.8
16.5
320
3.5
7/0.8
2.4
0.8
18.5
450
5.5
7/1.0
3.0
1.0
21.5
640
8
*
3.4
1.0
22
803
14
*
4.4
1.0
26
1330
22
*
5.5
1.2
31
2000
30
*
6.5
1.2
34
2640