Internal wiring of electrical equipment.
Specifications
1.Conductor:Annealed Copper Wire,(Bare Single,Tinned Single, Tinned Strand,or Top-Tinned Strand)2.Insulation: XLPVC (Cross – Linked Polyvinyl Chloride)3.Structure:
Conductor
Insulation
ConductorResistance(20℃)
AWG
Construction
Diameter
MinThickness
NominalThickness
Diameter
28
7 / 0.13TA
approx.0.39 mm
0.33 mm
0.41 mm
1.22 ± 0.10 mm
228.22W / Km
26
7 / 0.16TA
approx 0.48 mm
1.32 ± 0.10 mm
142.55W / Km
24
11 / 0.16TA
approx 0.61 mm
1.40 ± 0.10 mm
88.77W / Km
24
7 / 0.20TA
approx 0.60 mm
1.55 ± 0.10 mm
57.44W / Km
22
17 / 0.16TA
approx 0.76 mm
1.76 ± 0.10 mm
37.09W / Km
22
7 / 0.26TA
approx 0.78 mm
2.10 ± 0.10 mm
22.91W / Km
4.Characteristics:
Items
Specification
Rating
105℃ 300V
Dielectric Strength
AC 3000V / min.
Insulation Resistance
Min. 10MW - Km (20℃) at DC 500V
Flame Test
UL:VW-1 CSA:FT-1
Elongation of Insulation
Min.100 ﹪
Tensile Strength of Insulation
Min.1500Kg / mm2
Residual of Elongation after Aging
Min. 65 ﹪of original (136℃,168H)
Residual of Tensile Strength after Aging
Min. 70 ﹪of original (136℃,168H)
5.Marking:E54979 AWM 1430 105℃ 300V VW – 1 □AWG TATUNGLL58500 CSA REW(XLPVC) 105℃ 600V FT1